Principle of operation |
Magnetic Flux Leakage |
Detection |
18 off Hall Effect sensors |
Scan width |
150 mm |
Method of propulsion |
Hand Push / Pull |
Speed |
0.5 m/sec |
Handle |
Extendable handle supplied |
Profile |
Clearance under pipework required 120 mm |
Thickness range |
Maximum 15 mm |
Test through coatings |
Yes if non magnetic |
Maximum coating thickness |
6 mm |
Sensitivity |
adjustable |
Max sensitivity |
10% underfloor on un-coated 6 mm plate
20% underfloor on coated 6 mm plate |
Connecting Cable |
5 metre standard length |
Power requirements |
12v battery operation |
Test Time |
10 hour continuous working |
Transit case |
Meets IATA requirements for transporting magnetizable
material |
Operating weight |
18 Kg - combined weight of scanning head and electronics
module |